STRUCTURE AND WORKING PRINCIPLE
Two structures for removing liquid droplets from gas
Wire mesh pads and vane packs both collect entrained liquid droplets, using different internal structures. Understanding the installed type helps you specify a replacement and the information needed for an enquiry.
Knitted wire mesh demister
As gas passes through the knitted pad, droplets encounter wire surfaces through inertial impaction and interception. The collected liquid combines into larger drops and drains from the mesh.
- Porous knitted mesh pad
- Droplet capture on wire surfaces
- Mesh rolls, blanks and formed pads available from Sokay
Vane or blade-type demister
Shaped plates guide the gas through changes in direction. Droplets strike the vane surfaces, combine and drain away from the gas stream.
- Channels formed by shaped plates
- Droplet capture as the gas changes direction
- Different internal geometry and drainage arrangement
Replacing an existing separator
Review the installed structure, available space, flow conditions and drainage arrangement. Changing from mesh to vanes, or from vanes to mesh, also requires a review of the process and installation requirements.
- Existing part photos and equipment drawing
- Dimensions, supports and installation access
- Operating conditions and allowable pressure drop
START A CONVERSATION
Replacing a wire mesh demister pad?
Send the equipment drawing or clear photos, along with the pad dimensions and operating conditions, to discuss a replacement mesh pad.